ifm Electronic Magnetic-Inductive (Electromagnetic) Flow Meter

ifm Electronic Magnetic-Inductive (Electromagnetic) Flow Meter — SM6000 / SM8000 / SM7000 / SM4100 / SM4000 / SM4120 / SM600  | Shop On Ebay

Factory New Parts : Warranty 12 Months​
Refurbished Units : Warranty 3–6 Months​
Tested & Certified | Ships Worldwide​
Technical / Configuration Support Available​
Warranty Extension and Urgent Delivery supported. Get your quote or lead time now !

Description

The ifm SM series​ are magnetic-inductive (electromagnetic) flow meters​ for continuous volumetric flow measurement of conductive liquids​ (water, wastewater, acids, alkalis, slurries — min. conductivity ≥ 5 µS/cm).
  • SM6000 / SM8000​ → Advanced electromagnetic flow sensors with IO-Link, high accuracy (±0.5% o.r. ±1 mm/s), and programmable K-factor / flow totalizer.
  • SM7000​ → Compact inline magmeter for smaller DN sizes.
  • SM4100 / SM4000 / SM4120 / SM600​ → Earlier / economy variants — same Faraday principle, with 4–20 mA + pulse/frequency output (some with display).
These sensors have no moving parts, are immune to viscosity changes, and provide bidirectional flow information. They require a minimum fluid conductivity and are typically flange- or wafer-mounted.

Key Features

  • Measuring Principle: Faraday’s Law — U_ind ∝ v × B × L (flow velocity induces voltage in fluid)
  • Fluid Requirement: Conductivity ≥ 5 µS/cm (tap water OK; demineralized water < 5 µS/cm NOT measurable)
  • Output Options: 4–20 mA analog + pulse/frequency (for totalization) — IO-Link on SM6000/SM8000
  • Nominal Sizes (DN): Typically DN 15 … DN 300+ depending on model (SM6000 covers common mid-range DN)
  • Liner Material: PTFE, PFA, or hard rubber — selected per media compatibility
  • Electrode Material: Stainless steel 316Ti, Hastelloy C-276, Tantalum — per aggressive media
  • Country of Origin: Germany

Model Reference Table

Model Family
Feature Level
Output
IO-Link
Typical DN
Application
SM6000
Advanced programmable
4–20 mA + Pulse + Totalizer
Yes (select var.)
DN 25–200 (varies)
Process & water with diagnostics
SM8000
High-end (larger DN / options)
4–20 mA + Pulse + Totalizer
Yes (var.)
DN 50–300+
Large pipe / custody transfer
SM7000
Compact inline
4–20 mA + Pulse
Some vars.
DN 15–50
Compact machine / skid mount
SM4100 / SM4120
Economy / established design
4–20 mA + Pulse
No
DN 15–100
General water / waste
SM4000 / SM600
Legacy / basic
4–20 mA
No
Varies
Replacement / budget
⚠️ Critical Selection Criteria:
  1. Fluid Conductivity​ — must be ≥ 5 µS/cm (distilled/deionized water often < 1 µS/cm → NOT measurable!).
  2. Liner & Electrode Material​ — PTFE/PFA for chemicals; Rubber for abrasive slurry; Hastelloy/Tantalum for corrosive acids.
  3. DN (Nominal Bore)​ — match pipe ID; full-bore magmeters require straight upstream/downstream runs (5×/2× DN typical) unless flow conditioner used.
  4. Earthing Rings / Grounding Electrodes​ — mandatory for non-conductive lined pipes (PTFE/PFA).

Technical Specifications (Representative — SM6000 Electromagnetic Flow Sensor)

Parameter
Specification
Model Example
SM6000 (ifm Electronic) — exact suffix defines DN, liner, electrode
Measuring Principle
Electromagnetic induction (Faraday’s Law)
Measured Medium
Conductive liquids ≥ 5 µS/cm
Flow Range (Velocity)
0.01 … 10 m/s (typical usable 0.3 … 6 m/s for best accuracy)
Accuracy
±0.5 % of reading ± 1 mm/s (after zero calibration)
Repeatability
≤ 0.1 % of reading
Output Signal
4–20 mA (2-wire loop-powered, some 4-wire with sep. 24V) + Pulse/Freq. for totalization
Optional Digital Comm.
IO-Link (on SM6000 / SM8000 select variants)
Process Connection
Wafer (DIN/ANSI/JIS) or Flange — per ordered suffix
Nominal Diameter (DN)
DN 15 … DN 300+ (SM6000 typical DN 25–200)
Liner Material
PTFE, PFA, Hard Rubber (check suffix for media compatibility)
Electrode Material
1.4404 (316Ti SS), Hastelloy C-276, Tantalum, Titanium (suffix dependent)
Max. Process Pressure
Up to 40 bar (PN 40) — varies with DN & flange rating
Process Temp. Range
-20 … +120 °C (liner dependent; PTFE up to 180 °C short term)
Ambient Temp.
-20 … +60 °C
Electrical Connection
M12 × 8-pin (A-coded) or terminal box — per variant
Power Supply (Electronics)
24 V DC (loop-powered 2-wire for analog; 4-wire versions have sep. 24V for display/IO-Link)
Protection
IP65/IP67 (with mated connector / terminal box lid closed)
Standards
CE, UL (component), WRAS / KTW (potable water liners on select variants), RoHS

Warranty & After-Sales

  • Factory new units: 12 months warranty
  • Refurbished units: 3–6 months warranty (where offered)
  • Technical support for:
    • Sizing (DN selection based on expected min/max flow — aim 0.3–6 m/s velocity)
    • Liner & electrode material selection (chemical compatibility chart)
    • Zero-point calibration procedure (empty pipe filled with air → zero; filled with liquid → re-zero if needed)
    • IO-Link parameterization (K-factor, pulse value per liter/gallon, totalizer reset)
    • Earthing / grounding ring requirement explanation
  • Cross-reference vs. Endress+Hauser Promag / Krohne Optiflux / Yokogawa AXF if required

Delivery Time

  • Standard delivery: 3–5 working days (stock DN/spec — custom liner/electrode may be longer)
  • Express shipping available upon request

Why Choose Our Store

  • Genuine ifm Electronic flow measurement products
  • Global supply network with competitive pricing
  • Expertise in electromagnetic flow metering & IO-Link integration
  • Comprehensive technical documentation (dimensional drawings, K-factor tables, chemical resistance guide)
  • Responsive customer service and support

Applications

  • Water & wastewater treatment plants (raw/clean water, sludge)
  • Food & beverage (CIP solution, juice, milk — with FDA-liner & EHEDG design)
  • Chemical dosing (acid/alkali — PTFE liner + Hastelloy/Ta electrodes)
  • Pulp & paper (black liquor, white water — rubber liner + SS electrodes)
  • Machine-mounted coolant / lubricant flow monitoring
  • Irrigation & municipal water distribution