Omron SYSMAC CJ-series Temperature Control Unit

Omron SYSMAC CJ-series Temperature Control Unit — CJ1W-TC101 (2 Loops, Thermocouple/RTD, PID with Auto-Tuning) |  Shop On eBay

Factory New Parts : Warranty 12 Months​
Refurbished Units : Warranty 3-6 Months​
Tested & Certified | Ships Worldwide​
Technical / Configuration Support Available​
Warranty Extension and Urgent Delivery supported. Get your quote or lead time now !

Description

The Omron CJ1W-TC101​ is a Temperature Control Unit (TCU)​ for the SYSMAC CJ-series PLC, providing standalone PID temperature control directly in the PLC rack​ — no separate temperature controller (E5□C) is needed for simple to moderate heating/cooling loops.
  • CJ1W-TC101​ → 2 control loops (2 channels), supports Thermocouple (K, J, R, S, T, E, N, B, C, PLII — typical Omron TC list)​ and RTD (Pt100, JPt100)​ inputs, Transistor (NPN/open-collector) outputs​ for driving SSR or solid-state heater drivers, PID with Auto-tuning (AT), Self-tuning (ST), Heater Break Alarm (HBA — detects SSR/heater failure via current transformer or logic), and Loop Alarm (Deviation / PV high/low).
  • The module occupies 1 slot in a CJ rack​ (uses 16 input + 16 output words in the CIO area, plus DM area for setpoints/parameters — allocated automatically by CX-Programmer).
  • Configuration is done via CX-Thermo (bundled with CX-Programmer / CX-One)​ — you set input type, PID constants (or let AT determine them), alarm types, heater break detection, control period (typically 0.5 s – 99 s for SSR drive).
  • Compatible with CJ1M, CJ2M, CJ2H CPUs​ on a CJ1W-PA202/PA205 backplane.
Typical use: Plastic injection molding barrel zones, extruder barrel heat zones, ovens, environmental chambers — anywhere 1–2 temp loops per slot are needed and integrating into the PLC program is preferred over standalone controllers.

Key Features

  • Control Loops: 2 independent loops (CH1 / CH2)
  • Sensor Inputs: Thermocouple (K/J/R/S/T/E/N/B/C/PLII) & RTD (Pt100, JPt100) — per channel selectable
  • Control Outputs: Transistor NPN (open-collector, 24V DC sink) — typically to SSR for heater; can also be used with external SSR driver module (OMRON G3NA etc.)
  • Control Algorithm: PID with Auto-tuning (AT), Self-tuning (ST — adapts to process drift), ON/OFF control also possible
  • Alarm Functions: PV high/low, Deviation high/low, Heater Break Alarm (HBA — requires external CT or logic feedback — some TC101 versions support HBA via digital input or external CT like K8AK/K8DS paired)
  • Communications / Monitoring: Parameters accessible via PLC memory (CIO / DM) — can be monitored/altered from ladder or HMI linked to PLC
  • Country of Origin: Japan (Omron Corporation)

Model & Variant Reference (Omron CJ1W-TC Temperature Control Units — Context)

Model
Loops
Input Type
Output Type
Notes
CJ1W-TC101​ (listed)
2
TC / RTD (per ch)
Transistor NPN (SSR drive)
Most common — heats via SSR; AT/ST/PID
CJ1W-TC102
2
TC / RTD
Voltage (0–10V / 4–20mA — for analog power controller)
Less common — if driving analog SCR/controller
CJ1W-TC201
4
TC / RTD
Transistor NPN (SSR)
4-loop version (wider? — actually still 1 slot — 4 ch in same footprint)
E5CC/E5EC (standalone)
1
TC/RTD
Relay / SSR / Analog
Shown for contrast — CJ1W-TC101 replaces simple standalone TCs in integrated designs
⚠️ Critical Notes:
  1. SSR Drive Output — Not Relay Contact!: CJ1W-TC101 outputs are NPN open-collector transistor (typically 24V DC, 0.1A max sink)​ intended to drive a Solid State Relay (SSR — e.g., Omron G3NA-210B or G3NA-240B)​ which in turn switches the heater AC mains. They are NOT power contacts​ — do NOT connect heaters directly! Use SSR or mechanical contactor with SSR pilot.
  2. Wiring — Input Side: TC/RTD wires to dedicated terminals on front of TC101 — follow compensation lead rules (TC = compensating wire; RTD = 3-wire preferred). Shield drain wire to FG terminal on module.
  3. CIO/DM Allocation: In CX-Programmer, inserting CJ1W-TC101 auto-assigns a CIO block (e.g., CIO 100–101 for 2 words input status + 2 words output cmd — depends on start address you pick) and DM block for SV/PV/PID params. You read PV from allocated DM word, write SP to another DM word in ladder or via CX-Thermo.
  4. CX-Thermo Configuration: After HW insert → double-click TC101 → CX-Thermo launches → set Sensor Type (TC K / Pt100 etc.), Unit (°C/°F), Control Period (SSR drive typ. 0.5 s–2 s), AT mode (Run AT once or always-on ST), Alarm types, HBA (if used). Download to PLC.
  5. Heater Break Alarm (HBA): TC101 can detect heater/SSR failure if you provide a CT (current transformer on heater line — e.g., Omron K8DS-CT) feeding a digital input OR some versions allow inference from output state vs expected — check manual for exact HBA method on TC101 (some require external CT + DI wired back to PLC or dedicated HBA module CJ1W-HBA… — TC101 itself monitors output command consistency; true HBA with current sensing may need external CT + logic in CPU or separate HBA unit). Simplified: TC101 alarms if output ON but PV doesn’t rise (soft break detect) — true current-sense HBA often needs external CT.

Technical Specifications (CJ1W-TC101 — 2-Loop TC/RTD Temp Control Unit, SSR Transistor Output)

Parameter
Specification
Model / Order Code
CJ1W-TC101 (Omron SYSMAC CJ-series Temperature Control Unit — 2 loops)
Series
SYSMAC CJ (plugs into CJ backplane — occupies 1 I/O slot)
Control Loops
2 independent (CH1, CH2)
Input Signal (per ch)
Thermocouple: K, J, R, S, T, E, N, B, C, PLII; RTD: Pt100 (JIS/DIN), JPt100 — resolution 0.1°C (TC) / 0.1°C (RTD)
Control Output (per ch)
Transistor NPN open-collector (24 V DC, 0.1 A max sink) — for SSR drive (e.g., G3NA-210B DC input)
Control Method
PID with Auto-tuning (AT), Self-Tuning (ST — slow adapt), ON/OFF with hysteresis
Sampling Period
250 ms (input conversion) — control period selectable 0.5 s – 99 s (SSR drive period)
Alarm Types
PV HIGH, PV LOW, Deviation HIGH (SP±Δ), Deviation LOW — assignable per loop
Heater Break Alarm
Loop alarm (output ON but PV not responding — soft detect); true current-sense HBA typically via external CT + PLC logic or optional HBA unit — check Omron manual for TC101 HBA detail
Indicators (LED)
PWR (green — module powered), ALM (red — any alarm active), OUT1/OUT2 (yellow — output ON per ch — blink during AT)
Backplane I/F
CJ bus — auto CIO/DM allocation (typ. 2 words input area + 2 words output area in CIO; several DM words for SV/PV/PID)
Operating Temp.
0 … +55 °C (no freezing/dewing)
Dimensions (W×H×D)
31 mm (W) × 90 mm (H) × 65 mm (D) — standard CJ 1-slot width
Weight
~ 0.09 kg
Standards
CE, UL, cUL, KC, RoHS
Config. Software
CX-Programmer + CX-Thermo (part of CX-One) — V9.x+ recommended
Required PSU
CJ1W-PA202 (AC in) or CJ1W-PA205 (DC in) — not included

Warranty & After-Sales

  • Factory new units: 12 months warranty
  • Refurbished units: 3-6 months warranty (simulated input (mV source for TC equiv.) → verify PV read + SSR output pulse in auto/man mode)
  • Technical support for:
    • CX-Thermo setup walkthrough (insert TC101 → launch CX-Thermo → select sensor → set SP range → enable AT → download)
    • CIO/DM address allocation (how to read PV / write SP from ladder or HMI via PLC DM area)
    • SSR sizing & wiring (TC101 NPN → SSR DC- side (G3NA- (+) to +24V, (–) to TC101 output Y□ — sink type); AC heater side in SSR)
    • Thermocouple vs RTD wiring (comp wire for TC; 3-wire RTD preferred; shield drain to FG)
    • Alarm handling (read alarm bits in allocated CIO area → latch/annunciate on HMI)
    • Heater Break / HBA discussion (soft detect vs current CT method)
  • Optional: CJ1W-PA202/PA205 PSU, CJ2M CPU, SSR (G3NA-210B / G3NA-240B), thermocouple/RTD sensor, CX-One software

Delivery Time

  • Standard delivery: 3-5 working days (stock items)
  • Express shipping available upon request

Why Choose Our Store

  • Genuine Omron CJ1W-TC series — not third-party clone (TC input linearity critical)
  • Global supply network with competitive pricing
  • Expertise in Omron CJ temperature loop integration (TC101 + SSR + CX-Thermo + PLC/HMI link)
  • Comprehensive technical documentation (TC101 terminal wiring diagram, CX-Thermo screenshot, CIO/DM map, SSR interface example)
  • Responsive customer service and support

Applications

  • Plastic Injection Molding Barrel Zones: 2–4 zones per rack — CJ1W-TC101 (2 ch) or TC201 (4 ch) — PV to HMI, SP from recipe in PLC.
  • Extruder / Blown Film Die Zones: Multiple zones across CJ racks — integrate temp control into main machine PLC program.
  • Environmental Chamber / Oven: Heat + optional cool (reverse acting) — PID with AT gets you close first heat-up.
  • Retrofit from Standalone TC: Replace E5□C standalone controllers — consolidate into PLC rack, reduce panel space, unify setpoint entry via HMI.
  • R&D / Pilot Plant Skids: Easy integration with CJ2M + HMI — temp loops configured in minutes via CX-Thermo.