Schneider Electric TeSys LRD Thermal Overload Relay — LRD07C / LRD08C / LRD10C / LRD12C / LRD14C / LRD16C / LRD21C / LRD22C / LRD32C / LRD35C  

Schneider Electric TeSys LRD Thermal Overload Relay — LRD07C / LRD08C / LRD10C / LRD12C / LRD14C / LRD16C / LRD21C / LRD22C / LRD32C / LRD35C  | Shop On Ebay

Factory New Parts : Warranty 12 Months​
Refurbished Units : Warranty 3-6 Months​
Tested & Certified | Ships Worldwide​
Technical / Configuration Support Available​
Warranty Extension and Urgent Delivery supported. Get your quote or lead time now !

Description

The Schneider Electric TeSys LRD series​ are bimetal thermal overload relays (OLR)​ designed to clip directly onto TeSys D (LC1D) contactors, providing reliable motor overload, phase-loss, and prolonged overcurrent protection. The listed models — LRD07C (1.6–2.5A) through LRD35C (23–32A for larger frames, or 30–38A on LC1D38…D65 context)​ — cover the low-to-medium current range for controlling motors from 0.1 kW up to ~15 kW (400V AC-3). Each unit features an adjustable current dial, manual/auto reset, test button, trip flag indicator, and 1NO+1NC auxiliary contacts for breaking the coil circuit and signaling alarms to a PLC/HMI.

Key Features

  • Direct Snap-On Mounting: No extra wiring between contactor and OLR — mounts to front of LC1D09…D65 contactors.
  • Adjustable Trip Current: Dial-set to match motor Full Load Ampere (FLA).
  • Trip Class: Class 10A (trips in 2–10 sec at 10×In per IEC 60947-4-1).
  • Auxiliary Contacts: 1 × NC (95-96, early break — opens coil circuit on trip) + 1 × NO (97-98 — for alarm/PLC).
  • Phase Failure Sensitivity: Trips on loss of one phase.
  • Ambient Temp. Compensation: -20 °C to +60 °C compensated.
  • Country of Origin: France / Morocco / China (Schneider global)

Model & Setting Range Table

Model
Fits Contactor
Current Setting Range (A)
Typical Motor (400V AC-3)
LRD07C
LC1D09…D18
1.6 – 2.5 A
~0.55 kW
LRD08C
LC1D09…D18
2.5 – 4.0 A
~1.1 kW
LRD10C
LC1D09…D25
4.0 – 6.0 A
~1.5–2.2 kW
LRD12C
LC1D09…D25
5.5 – 8.0 A
~2.2–3 kW
LRD14C
LC1D09…D32
7.0 – 10.0 A
~3–4 kW
LRD16C
LC1D18…D38
9.0 – 13.0 A
~4–5.5 kW
LRD21C
LC1D25…D50
12.0 – 18.0 A
~5.5–7.5 kW
LRD22C
LC1D25…D50
17.0 – 23.0 A
~7.5–11 kW
LRD32C
LC1D32…D65
23.0 – 32.0 A
~11–15 kW
LRD35C
LC1D38…D65
30.0 – 38.0 A (some refs up to 40A)
~15–18.5 kW
⚠️ Selection Rules:
  1. Match OLR frame to contactor frame​ (LRD07–LRD35 → LC1D09…D65).
  2. Set dial to Motor FLA​ — NEVER to contactor rated current!
  3. Star-Delta starters need 2 OLRs: Main OLR = FLA; Delta-run OLR = FLA ÷ √3.
  4. “C” suffix = screw terminals​ on auxiliary contacts (control side).

Technical Specifications (Representative — LRD21C)

Parameter
Specification
Model
LRD21C
Series
TeSys LRD (Thermal Overload Relay)
Mounts On
LC1D25…D50 TeSys D contactor (front snap-on)
Current Setting Range
12 – 18 A (adjustable dial)
Trip Class
Class 10A (IEC 60947-4-1)
Rated Insulation Voltage (Ui)
690 V
Auxiliary Contact
1 NC (95-96, breaks coil) + 1 NO (97-98, alarm) — 5 A @ 240V AC
Reset Type
Manual / Automatic (selectable)
Test Button
Yes (simulates trip condition)
Phase Failure Protection
Yes
Ambient Compensation
Yes (-20…+60°C)
Dimensions (mm)
Matches LC1D25–D50 footprint — W≈45, H≈97, D≈95
Weight
~0.28 kg
Standards
IEC 60947-4-1, UL 508, CSA C22.2, CE, RoHS

Warranty & After-Sales

  • Factory new units: 12 months warranty
  • Refurbished units: 3-6 months warranty
  • Technical support for:
    • Correct OLR selection per motor nameplate FLA & contactor size
    • Star-delta / reversing starter OLR sizing
    • Wiring (95-96 in series with STOP button & contactor coil; 97-98 to fault input)
    • Trip class choice (Class 10 vs Class 20 for high-inertia loads)
  • Cross-reference vs. older LR1-D / 3UA series

Delivery Time

  • Standard delivery: 3-5 working days (stock items)
  • Express shipping available upon request

Why Choose Our Store

  • Genuine Schneider Electric TeSys components
  • Global supply network with competitive pricing
  • Expertise in motor control centers, star-delta starters & soft-starter bypass panels
  • Comprehensive technical documentation (setting tables, tripping curves, dimensional drawings)
  • Responsive customer service and support

Applications

  • Motor overload protection for pumps, fans, compressors, conveyors
  • Star-delta reduced voltage starters
  • Reversing / Two-speed motor starters
  • Industrial machines with LC1D contactor lineup
  • Retrofit of older thermal relays (LR1-D, 3UA) with modern TeSys LRD