描述
The 6SL3210-1PE□□□UL□ family represents Siemens SINAMICS G120 PM240-2 air-cooled power modules in blocksize format — the industry-standard modular inverter power stage for 3-phase 400V-class motor drives from 0.75 kW up to 4 kW (low overload) . These modules feature:
- Unfiltered design (UL1/UL0 suffix = no integrated line filter) with integrated braking chopper
- 3-phase 380–480 V AC input (±10%), 47–63 Hz
- Heavy Overload (HO) capability: 200% rated current for 3 s, 150% for 57 s, 100% for 240 s, ambient -10 to +50°C
- Light Overload (LO) capability: 150% rated current for 3 s, 110% for 57 s, 100% for 240 s, ambient -10 to +40°C
- Released for CU firmware V4.6+ — compatible with CU240E-2, CU250S-2, CU310-2 control units
- IP20 protection, DIN-rail / cabinet mounting
All five models (1PE13-2UL1, 1PE14-3UL1, 1PE16-1UL1, 1PE18-0UL1, 1PE21-1UL0) belong to the same PM240-2 family but cover different power ranges. The “-UL1” suffix (1PE13/14/16/18) indicates FSA frame size; the “-UL0” suffix (1PE21) indicates FSB frame size .
Key Features
- SINAMICS PM240-2 power module — modular design pairs with G120 CU control units
- Unfiltered + integrated braking chopper — no external brake resistor needed for typical decelerations
- 3-phase 380–480 V AC input (±10%), 47–63 Hz
- Output: 3-phase 400V IEC / 480V NEC, 0–550 Hz (V/f), 0–200 Hz (vector control)
- Pulse frequency: 4 kHz (adjustable for noise/heat trade-off)
- Dual overload ratings — HO (heavy duty) & LO (light duty) for flexible motor matching
- Efficiency >96% per IEC 61800-9-2
- IP20 protection, UL open type
- Compact frames: FSA (73 × 196 × 165 mm) for 0.75–3 kW; FSB (100 × 291 × 165 mm) for 4 kW
- CU firmware V4.6+ approved
- Country of Origin: Great Britain (Siemens)
Technical Specifications — Model-by-Model Comparison
Parameter | 1PE13-2UL1 | 1PE14-3UL1 | 1PE16-1UL1 | 1PE18-0UL1 | 1PE21-1UL0 |
|---|---|---|---|---|---|
Frame Size | FSA | FSA | FSA | FSA | FSB |
Rated Power (HO) | 0.75 kW | 1.1 kW | 1.5 kW | 2.2 kW | 3 kW |
Rated Power (LO) | 1.1 kW | 1.5 kW | 2.2 kW | 3 kW | 4 kW |
Output Current (HO) | 2.2 A | 3.1 A | 4.1 A | 5.9 A | 7.7 A |
Output Current (LO) | 3.1 A | 4.1 A | 5.9 A | 7.7 A | 10.2 A |
Base-load Current (IH) | 1.7 A | 2.2 A | 3.1 A | 4.1 A | — |
Max. Output Current | 4.7 A | 6.2 A | 8.9 A | 11.8 A | — |
Efficiency (IEC 61800-9-2) | >96.7% | >97.1% | >97.3% | >97.3% | — |
Power Loss @ Rated | 0.037 kW | 0.047 kW | 0.057 kW | 0.080 kW | — |
Dimensions (W×H×D) | 73×196×165 mm | 73×196×165 mm | 73×196×165 mm | 73×196×165 mm | 100×291×165 mm |
Weight | ~1.4 kg | ~1.4 kg | ~1.4 kg | ~1.4 kg | ~3.1 kg |
Common Specifications (all 5 models):
Parameter | Specification |
|---|---|
Input Voltage | 3-phase AC 380–480 V (±10%) |
Input Frequency | 47–63 Hz |
Output Voltage | 3-phase 400V IEC / 480V NEC |
Output Frequency | 0–550 Hz (V/f), 0–200 Hz (vector) |
Pulse Frequency | 4 kHz |
Overload (HO) | 200% × 3 s, 150% × 57 s, 100% × 240 s (-10 to +50°C) |
Overload (LO) | 150% × 3 s, 110% × 57 s, 100% × 240 s (-10 to +40°C) |
Integrated Braking Chopper | Yes (no external brake resistor needed for typical loads) |
Line Filter | None (UL1/UL0 = unfiltered; use -AL1/-AL0 variants for Class A filter) |
Protection Class | IP20 (UL open type) |
Cooling | Internal forced air, 0.005 m³/s (FSA) |
Control Unit Required | CU240E-2 / CU250S-2 / CU310-2 (firmware V4.6+) |
Operator Panel | Not included (order separately: BOP-2 or IOP-2) |
Communication | Via CU: PROFIBUS, PROFINET, USS, Modbus RTU, EtherNet/IP |
Certifications | CE, UL, cUL, C-Tick (RCM), SEMI F47 |
Compliance | Low-voltage directive 2006/95/EC |
Mounting | Cabinet installation, vertical orientation |
Max Motor Cable Length | Shielded 50 m / Unshielded 100 m (FSA) |
Country of Origin | Great Britain |
Selection Guide — Which Model Do You Need?
Your Motor Power | Heavy-Duty Application (HO) | Light-Duty Application (LO) | Correct Model |
|---|---|---|---|
0.75 kW | ✅ 0.75 kW | — | 1PE13-2UL1 (1.1 kW LO) |
1.1 kW | ✅ 1.1 kW | — | 1PE14-3UL1 (1.5 kW LO) |
1.5 kW | ✅ 1.5 kW | — | 1PE16-1UL1 (2.2 kW LO) |
2.2 kW | ✅ 2.2 kW | — | 1PE18-0UL1 (3 kW LO) |
3 kW | ✅ 3 kW | — | 1PE21-1UL0 (4 kW LO) |
4 kW | — | ✅ 4 kW | 1PE21-1UL0 |
💡 HO vs LO explained: HO (Heavy Overload) is for tough applications — cranes, hoists, extruders, presses — where 200% peak torque is needed. LO (Light Overload) is for fans, pumps, compressors — variable torque loads where 150% peak is sufficient. Most general-purpose motors use the HO rating for safety margin.
Warranty & After-Sales
- Brand new units: 12 months warranty
- Refurbished units: 3-6 months warranty
- Bench test: 380–480V AC power-up → DC bus charges → braking chopper test → load test with simulated motor (verified at rated current per model) → overload trip test (200%/3s) → temperature rise test → insulation test
- Technical support:
- Model selection — we help you pick the correct power module based on your motor power, duty cycle (HO vs LO), and overload requirements
- CU pairing — we verify compatibility with CU240E-2, CU250S-2, or CU310-2 control units (all require firmware V4.6+)
- Filtered vs unfiltered — UL1/UL0 = unfiltered; if you need IEC/EN 61800-3 Class A EMC compliance, we recommend the -AL1/-AL0 filtered variants
- Braking resistor sizing — although a braking chopper is integrated, for high-inertia loads you may need an external braking resistor; we calculate the correct wattage
- G120 full system configuration — we supply the complete drive: power module + CU + BOP-2/IOP-2 + communication module (if needed) + motor cable
- Migration from MM440 / MM420 — if upgrading from legacy MICROMASTER drives, we map the equivalent G120 PM240-2 + CU240E-2 configuration
- CU firmware update — we flash CU firmware to V4.6+ before shipment for immediate compatibility
- Optional accessories: CU240E-2 PN/DP control unit, CU250S-2 control unit, BOP-2 basic operator panel, IOP-2 intelligent operator panel, PROFIBUS/PROFINET communication module, SINAMICS SD card (512MB), motor cable, braking resistor (for high-inertia loads)
Delivery Time: 3-5 working days (standard) / Express available
⚠️ IMPORTANT — Read Before Ordering:
This is a POWER MODULE ONLY — you MUST add a CU (control unit) to make a working inverter. We can supply the complete G120 drive (power module + CU) as a kit. Verify your motor power — select the model based on HO (heavy duty) rating for most industrial applications Unfiltered design — if your site requires EMC Class A compliance, choose the “-AL1/-AL0” filtered variants instead CU firmware V4.6+ required — older CU firmware will not recognize these power modules Send us your motor nameplate (power, voltage, current, duty cycle) — we’ll confirm the exact model and provide a complete G120 bill-of-materials
Why Choose Our Store
- Genuine Siemens PM240-2 power modules — no counterfeit risk (the IGBT power stage, braking chopper, and DC bus capacitor are factory-calibrated; clones fail overload tests, overheat, and have no valid CU communication)
- Full SINAMICS G120 family stock: PM240-2 power modules (FSA/FSB/FSC/FSF), CU control units (CU240E-2/CU250S-2/CU310-2), operator panels (BOP-2/IOP-2), communication modules
- Expertise in G120 system configuration (model selection, HO/LO rating, CU pairing, filtered/unfiltered decision, braking resistor sizing, firmware V4.6+ flashing, MM440 migration)
- Comprehensive technical documentation (dimensional drawings, power module + CU compatibility matrix, EMC filter selection guide, braking resistor sizing chart, G120 commissioning manual)
- Responsive customer support
Applications
- Conveyor & material handling — 1PE13/14/16/18 power modules drive 0.75–2.2 kW conveyor motors with HO rating for start-stop, reversing, and load surges
- Pumps & fans — 1PE16/18/21 with LO rating (2.2–4 kW) for centrifugal pumps, HVAC fans, cooling towers — 150% overload sufficient for variable torque
- Compressors — 1PE16/18/21 for refrigeration, air compression — HO rating handles high breakaway torque
- Machine tools — 1PE13–21 across the range for spindle drives, coolant pumps, hydraulic units with precise speed control via CU250S-2 + encoder
- Packaging machinery — 1PE13–18 for 0.75–2.2 kW servo-like applications using CU250S-2 vector control
- Textile & printing — 1PE16/18/21 for tension control, web handling with CU250S-2 closed-loop vector
- Renewable energy — 1PE21 for 4 kW pitch drive motors in wind turbines
- Food & beverage — 1PE13–21 for mixers, fillers, cappers, pasteurizers with hygienic washdown (IP20 inside cabinet)
- G120 retrofit / spare parts — 1PE13–21 as direct replacements for failed PM240-2 modules in existing G120 installations
- OEM machine builders — complete G120 kits (PM240-2 + CU240E-2 PN + BOP-2) for standard 0.75–4 kW machine integrations