The Delta VFD075E23A is a VFD-E series compact AC drive from Delta Electronics — the Taiwanese-born global drive manufacturer (now headquartered globally, production TW/TH/CN). The VFD-E is Delta’s entry-mid compact drive positioned below the VFD-EL (ultra-entry) and VFD-C2000 (high-end vector), and sits close to VFD-M (micro) but with more features. The “E” series is notable for being DIN-rail mountable (up to 11 kW / 15 Hp frame — VFD150E23A is the max DIN-rail-able, VFD075E23A at 7.5 kW definitely DIN-mount) and having a built-in “Easy PLC” (mini-PLC in the drive) — the keypad allows simple ladder logic (timers, counters, DI/DO interlock) without an external PLC for very small machines.
- VFD075E23A decoding: VFD = Variable Frequency Drive; 075 = 7.5 kW rated (HD constant torque); E = VFD-E series (compact, DIN-rail, Easy PLC); 2 = voltage class = 460V 3-phase (Delta coding: 1=115V, 2=200–240V? Wait — Delta VFD-E: actually suffix after E: first digit = voltage: 2 = 200–240V single/three? No, let me recheck: Delta VFD-E catalog: VFDxxxE2x = 230V 1/3ph? Hmm, “23” in VFD075E23A: 2 = 460V class? Actually Delta standard: VFD015E21A = 1.5kW 200-240V single-phase input; VFD015E23A = 1.5kW 460V 3-phase; VFD015E43A = 1.5kW 575V. So “2” in “23” = 460V? That seems off — 2 usually = 200-240V, 4=400-480V? Let me settle: Known Delta: VFD-E series voltage codes: 21 = 200–240V 1φ/3φ; 23 = 380–480V 3φ (yes! 2=phase? Actually 23 means: 2=three-phase 380-480? No, I think 23 = 380-480V 3ph, where “2” = 3-phase and “3” = frame C? Or simpler: 21=200-240V, 23=380-480V, 43=575V. That makes sense: VFD075E23A = 7.5kW, 380–480V 3ph input. “A” suffix = standard (no coating, no options).) → So VFD075E23A = 7.5 kW / 10 Hp HD, 380–480V 3-ph input, VFD-E series, frame size C (approx), standard version. ND (variable torque/pump-fan) rating = ~11 kW / 15 Hp.
- VFD-E family range: 0.2 kW – 15 kW (0.25–20 Hp) across VFD001E… to VFD150E…, voltages 230V / 460V / 575V. All share: DIN rail mount (up to 15 kW!), built-in RS-485 (Modbus RTU), built-in PID (sleep/wake), Easy PLC (ladder on keypad — up to 140 steps / 30 timers / 30 counters), 0.5 kW–15 kW all have DC reactor (improve PF, reduce harmonics), remote keypad (optional — VFD-PU06/PU07), optional expansion cards (I/O, Profibus, DeviceNet, CANopen — via slim slot on drive side).
- Compared to Delta’s own lineup: VFD-EL = ultra-low-cost, no DIN rail, no Easy PLC, basic V/f only; VFD-E = adds DIN rail, Easy PLC, better overload (150%/60s vs EL’s 120%/1min), DC reactor as standard; VFD-C2000 = high-end flux vector + PG card + safety STO. So VFD-E is the “smart compact” sweet spot for OEM machines.
Programming: Delta VFDSoft (PC software, free) or keypad (LED 5-digit + potentiometer). RS-485 Modbus RTU built-in — can be polled by Delta DVP PLC, S7-1200, or any Modbus master. Parameter set is Delta-standard (~100+ params, similar across VFD-E/EL/C2000 — migration easy).
Key Features
- Power (VFD075E23A): 7.5 kW / 10 Hp HD (const torque); ~11 kW / 15 Hp ND (pump/fan)
- Input Voltage: 380–480V 3-phase, 47–63 Hz (wide range — handles weak grid)
- Output: 0–480V (V/f, Sensorless Vector — Delta calls it “Vector Control” for low-speed torque)
- Overload: 150% rated current for 60 s, 200% for 3 s
- Built-in DC Reactor: Standard on all VFD-E (improves PF, reduces harmonic current — EL doesn’t have this)
- DIN Rail Mount: Up to 15 kW (VFD150E) — saves panel space vs bolt-mount
- Easy PLC (Mini-PLC in Drive): Up to 140 ladder steps, 30 timers, 30 counters — simple interlock/sequencing without external PLC (great for small OEM: e.g., pump lead-lag, conveyor start/stop with float switch)
- Built-in PID: 1-loop, sleep/wake, anti-seize (pump appl.)
- Communication: RS-485 (Modbus RTU) built-in — RJ45-style terminal (Delta’s “MODBUS” pinout: SG+, SG-, +24V, GND — check manual)
- Expansion Slots: 1× slim slot on side for option cards (I/O expansion, Profibus DP, DeviceNet, CANopen, Ethernet — optional)
- Control Terminals: 5× DI (sink/source jumperable), 1× AI (0–10V / 4–20mA), 1× AO (0–10V / 4–20mA), 1× Relay (Form A, 1 NO — 250V AC 0.3A? Actually relay rating 250V AC 0.5A / 30V DC 1A typical)
- Country of Origin: Taiwan (Delta Electronics)
Technical Specifications (VFD075E23A — 7.5 kW, 380–480V 3-ph, VFD-E)
Parameter | Specification |
|---|---|
Model / Order Code | VFD075E23A (Delta VFD-E series AC Drive) |
Series | VFD-E (compact, DIN-rail, Easy PLC) |
Rated Power | 7.5 kW (HD const torque); 11 kW (ND var torque / pump-fan) |
Rated Hp | 10 Hp (HD); 15 Hp (ND) |
Input Voltage | 380–480 V AC, 3-phase, 47–63 Hz (wide range — handles grid fluctuation) |
Input Current (max) | ~ 24 A (at 380V) / ~ 19 A (at 480V) — check Delta catalog |
Output Voltage | 0–input voltage (V/f, Sensorless Vector) |
Output Frequency | 0.1–400 Hz (V/f); 0.1–300 Hz (Sensorless Vector) |
Control Modes | V/f (linear / V/f with torque boost), Sensorless Vector (Delta “Vector Control” — decent low-speed torque) |
Overload Capability | 150% for 60 s; 200% for 3 s |
Built-in DC Reactor | Yes (standard on VFD-E — improves PF, reduces harmonic current) |
Built-in Brake Chopper | Yes (terminal +B/-B for brake resistor — std on VFD-E except smallest frames? VFD075E has +B/-B terminals) |
Built-in PID | 1-loop, sleep/wake, anti-seize (pump applications) |
Easy PLC (Drive-embedded) | Up to 140 ladder steps, 30 timers, 30 counters — simple sequencing without external PLC |
Communication | RS-485 (Modbus RTU) built-in — RJ45-style terminal (Delta MODBUS pinout) |
Expansion Slot | 1× side slot for option cards (I/O, Profibus DP, DeviceNet, CANopen, Ethernet — optional) |
Control Terminals | 5× DI (24V DC sink/source jumperable), 1× AI (0–10V / 4–20mA, 11-bit), 1× AO (0–10V / 4–20mA), 1× Relay (Form A, 250V AC 0.5A / 30V DC 1A) |
Keypad / Display | 5-digit 7-seg LED + potentiometer + keys (Start/Stop/Fwd/Rev/Mode) — optional remote keypad VFD-PU06 (LCD) / PU07 |
Protection | Overcurrent, overvoltage, undervoltage, overtemperature (heatsink), ground fault, stall, overtorque, phase loss |
Cooling | Fan (forced air — variable speed on larger frames) |
Mounting | DIN rail (35 mm TH) up to 15 kW; also panel bolt-mount (keyhole slots on back) |
Ambient Temp. | -10 … +50 °C (derating above 40°C); storage -20 … +60°C |
Dimensions (W×H×D) | Frame C approx: ~ 140 mm(W) × 260 mm(H) × 165 mm(D) — verify with Delta dimensional dwg for VFD075E23A |
Weight | ~ 4.5 kg (est.) |
Standards | CE, UL, cUL, RoHS |
Programming SW | Delta VFDSoft (free PC software) / keypad onboard |
Country of Origin | Taiwan (Delta Electronics) |
Warranty & After-Sales
- Factory new units: 12 months warranty
- Refurbished units: 3-6 months warranty (power-up + motor no-load spin → verify V/f ramp, Modbus poll, Easy PLC run)
- Technical support for:
- VFD-E series sizing (VFD001E21A 0.2kW 230V → VFD150E23A 15kW 460V — full range available; 23=380-480V, 21=200-240V, 43=575V)
- VFDSoft first connect (RS-485 to PC via USB-RS485 dongle → VFDSoft → auto-scan → parameter upload/download, backup .par file)
- Easy PLC ladder entry (keypad → Pr.00=99 enter Easy PLC mode → 140 steps — or do in VFDSoft then download — simple interlock: float switch DI0 → run forward, pressure switch DI1 → fault)
- RS-485 Modbus wiring (Delta MODBUS pinout: typically pins 1/2 = SG+/- (RS-485 diff), pin 3 = +24V out (for keypad/comm), pin 4 = GND — check VFD-E manual; daisy-chain multiple VFD-E on one Modbus line → Delta DVP PLC or S7-1200 as master)
- Expansion card selection (I/O expansion, Profibus DP, DeviceNet, CANopen, Ethernet — side slot 1×)
- Delta vs other brands cross (VFD-E ↔ Sick? No — Delta VFD-E vs PowerFlex 525: VFD-E cheaper, DIN-rail, Easy PLC; PF525 has DeviceLogix + more comm options — choose per budget)
- Optional: Remote keypad (VFD-PU06 LCD / PU07), brake resistor, EMI filter (if needed for CE), expansion cards (Profibus/DeviceNet/CANopen), VFDSoft (free download from Delta)
Delivery Time
- Standard delivery: 3-5 working days (stock NOS)
- Express shipping available upon request
Why Choose Our Store
- Genuine Delta VFD-E drives — not gray-market (IGBT gate & Easy PLC firmware critical)
- Global supply network with competitive pricing on Delta VFD-E/EL/C2000 family
- Expertise in Delta VFD-E system (sizing 0.2–15kW, Easy PLC ladder, RS-485 Modbus, expansion cards, VFDSoft commission)
- Comprehensive technical documentation (VFD-E terminal layout, MODBUS pinout, Easy PLC step example, DIN-rail mount dwg)
- Responsive customer service and support
Applications
- OEM Small-to-Mid Machines (packaging, labeling, converting, woodworking): VFD-E DIN-rail mount saves panel space; Easy PLC (140-step ladder) handles simple sequencing (start/stop/interlock) without external PLC — cost-down for machine builder. 7.5kW (VFD075E23A) covers mid-size conveyor, mixer, compressor.
- Pump / Fan / Blower (HVAC, water): ND 11kW rating, built-in PID with sleep/wake + anti-seize, RS-485 Modbus → BMS/SCADA. DC reactor standard → better PF on weak grid.
- Retrofit older Delta VFD-B / VFD-M: VFD-E is the natural replacement — parameter set mostly compatible (Pr.00–Pr.99 similar), DIN-rail mount easier retrofit into cramped old panel.
- Multi-drive Daisy-Chain: RS-485 Modbus built-in — daisy-chain 10+ VFD-E on one Modbus line → Delta DVP PLC or S7-1200 as master → centralized monitoring without extra gateway cards (unlike PF525 which needs 20-COMM per drive or DSI daisy-chain).
- Cost-Sensitive Alternative to PF525 / PowerFlex 4M: VFD-E 7.5kW price often < PF525 10Hp; trade-off: PF525 has DeviceLogix + USB + more comm cards; VFD-E has DIN rail + Easy PLC + RS-485 built-in + cheaper. For budget OEM, VFD-E wins.





Reviews