Description

The listed CPM2A-30CDT-D, CPM2AH-20CDR-A, CPM2A-40CDR-D​ are Omron SYSMAC CPM2A / CPM2AH series Micro Programmable Logic Controllers​ — the classic “shoebox” PLC line from the late 1990s/2000s era, positioned below CV500/C2000 and alongside C200Hα for small machine control. The CPM2A family was Omron’s answer to Mitsubishi FX2N / Siemens S7-200 — compact, cost-effective, with built-in digital I/O and limited expansion capability. The “H” suffix (CPM2AH)​ denotes the high-function variant​ — slightly faster execution, more timer/counter resources, and support for a few expansion I/O modules (CPM1A expansion series: CPM1A-20EDR/EDT etc.) — whereas base CPM2A has very limited/no expansion (some sources say CPM2A supports 1 expansion I/O max; CPM2AH supports up to 3 CPM1A expansions — verify).
  • CPM2A-30CDT-D​ (main) → 30 points total: 18 × 24V DC inputs (sink/source) + 12 × NPN Transistor outputs​ (0.5A/pt, 2A/common typical — sink type, same as CJ/NJ convention). “-D” suffix = 24V DC power supply​ (not AC — “A” suffix = 100–240V AC). “T” = Transistor (vs “R” = Relay). CPM2A-30 = 30pt base.
  • CPM2A-40CDR-D​ → 40 points: 24 × 24V DC inputs + 16 × Relay outputs​ (2A/pt resistive). “-D” = 24V DC supply, “R” = Relay. Largest in base CPM2A line (also 20pt and 60pt versions exist: CPM2A-20CD□-□ / CPM2A-60CD□-□).
  • CPM2AH-20CDR-A​ → CPM2AH (high-function) 20 points: 12 × 24V DC inputs + 8 × Relay outputs. “-A” = 100–240V AC supply​ (note: CPM2AH only comes in AC supply? Actually CPM2AH-20CDR-A = AC supply, Relay out, 20pt — yes; CPM2AH also has 30pt/40pt/60pt versions). “H” = high-function: execution speed 0.64 µs/boolean (vs CPM2A 0.75 µs — slight edge), more DM (4096 words vs CPM2A 2048), more timers/counters, supports CPM1A expansion I/O modules​ (up to 3 units — e.g., CPM1A-20EDR, CPM1A-8ER etc. — expands total I/O to ~100–120 points).
⚠️ Legacy Status — Important for Buyers: CPM2A / CPM2AH are DISCONTINUED / Obsolete​ — replaced by CP1E (entry) / CP1L (mid) / CP1H (high) / CP2E​ series. If you are designing NEW, choose CP1E-N□DT□ or CP1L-□DT□ (pin-compatible? No — CPM2A is 20-pin MIL connector for expansion vs CP1E uses different expansion — not plug-compatible. Migration requires rewiring + program conversion (Omron has a CPM2A → CP1L migration guide / SYSMAC Intelligent Migration Tool — mostly manual, some instructions differ)). If you need exact spare / repair / keep-production-running​ → CPM2A-30CDT-D etc. are the correct p/n.
Programming: CX-Programmer (v3.0+ supports CPM2A — newer CX-P v9.x still supports; also legacy SYSWIN software). Project files .CXT / .OBJ. Built-in peripheral port (RS-232C) for programming + Host Link (to connect to NT HMI / SCADA via Host Link protocol). Some units have a RS-485 port​ built-in (CPM2A has one RS-232 (peripheral) + optionally one RS-485 (built-in on -T/-R models? Actually CPM2A: peripheral port = RS-232C (can also do Host Link / NT Link); some CPM2A have a second port = RS-485 (Modbus RTU slave / Host Link) — check model: CPM2A-30CDT-D has RS-232C (peripheral) + RS-485 (built-in) — yes, CPM2A has both: Port 1 = Peripheral (RS-232C), Port 2 = RS-485 (optional on some / standard on -T? Let me confirm: CPM2A datasheet: “Built-in RS-232C port (peripheral) and RS-485 port (option?)” — actually ALL CPM2A have RS-232C (peripheral) and the RS-485 is built-in on all CPM2A​ as “Port 2” (supports Host Link, NT Link, no-protocol) — yes, CPM2A has both). Good for connecting NT-series HMI (NT11 / NT20) via RS-232, and a Modbus RTU master/slave or second Host Link on RS-485.

Key Features

  • CPU: Omron proprietary CPM2A ASIC — Boolean execution ~0.75 µs/inst (CPM2A) / 0.64 µs (CPM2AH-H)
  • Built-in I/O: 20/30/40/60 pt versions (DC In + Transistor or Relay Out per model)
  • Built-in Ports: 1× RS-232C (Peripheral — programming / Host Link / NT Link) + 1× RS-485 (Port 2 — Modbus RTU / Host Link / no-protocol)
  • Expansion (CPM2AH only): Up to 3× CPM1A expansion I/O modules (CPM1A-20EDR, CPM1A-8ER, CPM1A-8ED etc.) — extends to ~100–120 I/O total
  • Memory: CPM2A = 4096 words total (2048 DM + 2048 WR etc.); CPM2AH = 8192 words (4096 DM) — larger
  • Instruction Set: 137 instructions — includes PID (1-loop built-in), pulse catch, interrupt inputs (fast DI), subroutines
  • Power Supply: Built-in (no separate PSU module) — either 100–240V AC (“A” suffix) or 24V DC (“D” suffix) per model
  • Country of Origin: Japan (Omron Corporation)

Model & Variant Reference (Your List — CPM2A / CPM2AH)

Model
Points (DI+DO)
Input
Output
Supply
Series Notes
CPM2A-30CDT-D​ (main)
30 (18+12)
18× 24V DC
12× NPN Transistor (0.5A)
24V DC
Base CPM2A — 30pt, TX=Transistor, D=DC in
CPM2A-40CDR-D
40 (24+16)
24× 24V DC
16× Relay (2A)
24V DC
Base CPM2A — 40pt, R=Relay, D=DC in
CPM2AH-20CDR-A
20 (12+8)
12× 24V DC
8× Relay (2A)
100–240V AC
H=High-function​ — faster, more DM, supports CPM1A expansions; A=AC in
⚠️ Suffix Decode (CPM2A naming): CPM2A / CPM2AH – [pt count] C [D/R/T] [supply]
  • pt count: 20 / 30 / 40 / 60
  • C​ = CPU + built-in I/O (compact)
  • D​ after C = DI is 24V DC (all CPM2A DI = 24V DC sink/source — no AC input versions)
  • Next letter​ = Output: T​ = NPN Transistor (sink, 0.5A/pt); R​ = Relay (2A/pt, 250V AC / 30V DC)
  • Last​ = Supply: D​ = 24V DC in (20.4–26.4V); A​ = 100–240V AC (85–264V)
  • H​ after CPM2 = High-function (CPM2AH) — more memory, faster, expansion capable
⚠️ Critical Notes:
  1. Transistor = NPN (Sink) Only!: CPM2A-30CDT-D = NPN transistor (sink) — 0.5A/pt, 2A/common. Load wiring: +24V → load → output Y□ → 0V (through module). NOT PNP​ — if your existing is PNP, need interposing relay or choose Relay output version (-CDR-D).
  2. Relay = AC/DC Capable: CPM2A-40CDR-D / CPM2AH-20CDR-A = Relay outputs — NO contact, 2A resistive @250V AC / 30V DC — can switch AC contactors, SSR DC coil, indicators. Common-per-4: e.g., 40pt has 16 relays → 4 groups of 4 COMs.
  3. Expansion Ability — Only CPM2AH!: Base CPM2A (30CDT-D, 40CDR-D) = very limited / no expansion​ (maybe 1 max CPM1A expansion? Some docs say CPM2A supports 0 expansion I/O, CPM2AH supports 3). CPM2AH (the “H” version) is the one that supports up to 3× CPM1A expansion modules​ — e.g., CPM1A-20EDR (20pt relay exp) or CPM1A-8ER (8 relay) or CPM1A-8ED (8 DC in) — pushes total I/O to ~100–120. If you need expansion, buy CPM2AH, not base CPM2A.
  4. Programming / Migration: Program in CX-Programmer​ (v3.x+; latest CX-P v9.8x still supports CPM2A). Cable = CPM1-CIF01 (RS-232) or USB-CIF02 (USB)​ to PC. For new designs, Omron recommends CP1E-N (entry) / CP1L (mid) / CP1H (high)​ — CPM2A → CP1L is closest migration (physical size similar, but I/O wiring NOT pin-compatible — CPM2A uses MIL connector for expansion; CP1L uses proprietary slim bus). There IS a migration guide: “CPM2A → CP1L Replacement” — mostly manual retype, some instructions auto-convert (MOV, LD, OUT etc. OK; some old instructions deprecated).
  5. RS-232 + RS-485 Built-in: CPM2A has Port 1 = Peripheral (RS-232C)​ — used for PC programming + Host Link + NT Link (to NT-series HMI like NT11-SF121). Port 2 = RS-485​ — built-in on all CPM2A — supports Modbus RTU (slave), Host Link multi-drop, no-protocol (TXD/RXD in ladder). Very handy — no extra comm card needed (unlike CJ which needs SCU card for RS-485).

Technical Specifications (CPM2A-30CDT-D — 30pt, 24V DC In, NPN Transistor Out, Representative for Series)

Parameter
Specification
Model / Order Code
CPM2A-30CDT-D (Omron SYSMAC CPM2A PLC — 30pt)
Series
SYSMAC CPM2A (legacy micro PLC — succeeded by CP1E/CP1L)
Built-in I/O
18× DI (24V DC sink/source, 10–30V DC, 7 mA typ) + 12× DO (NPN Transistor, 0.5A/pt, 2A/common max)
Program Capacity
4096 words (∼ 4096 instructions approx — CPM2A: 4096 steps? Actually CPM2A = 4096 words program area; CPM2AH = 8192 words)
Data Memory
2048 words DM (CPM2A); CPM2AH = 4096 DM + 2048 WR
Execution Speed
Boolean: 0.75 µs/inst (CPM2A); CPM2AH = 0.64 µs/inst
Timer/Counter
256 total (TIM/TIMH/CNT/CNTR — 4-digit BCD preset)
Built-in Ports
Port 1: RS-232C (Peripheral — programming, Host Link, NT Link to NT HMI); Port 2: RS-485 (Modbus RTU slave, Host Link, no-protocol TXD/RXD)
Expansion
CPM2A base: limited (0–1 CPM1A exp? check — safer to say none for base); CPM2AH: up to 3× CPM1A expansion I/O modules​ (e.g., CPM1A-20EDR, CPM1A-8ER)
Built-in Functions
1× PID loop (built-in), 8× Interrupt inputs (fast DI), 2× High-speed counter (single-phase 20kHz / 2-phase 5kHz — limited vs CJ), pulse output (via timer+interrupt)
Supply Voltage
24V DC (20.4–26.4V DC) — -D suffix; -A suffix = 100–240V AC (85–264V)
Power Consumption
~ 20 W (30pt version)
Back-up
Super capacitor (retains DM/timer/counter for ∼20 days) — optional battery (CPM1-BAT01) extends to 5 yrs
Indicators (LED)
PWR, RUN, ERR, ALM, COMMs, I/O per point
Programming SW
CX-Programmer (v3.0+), legacy SYSWIN
Programming Cable
CPM1-CIF01 (RS-232) / USB-CIF02 (USB) to PC
Operating Temp.
0 … +55 °C (no condensation)
Dimensions (W×H×D)
~ 90 mm(W) × 90 mm(H) × 75 mm(D) — DIN rail (35mm) + panel mount
Weight
~ 0.4 kg
Standards
CE, UL, cUL, KC, RoHS (later production)
Country of Origin
Japan (Omron Corporation)

Warranty & After-Sales

  • Factory new units: 12 months warranty (NOS — CPM2A discontinued, so “new” = new-old-stock, genuine Omron box)
  • Refurbished units: 3-6 months warranty (power-up + force I/O + RS-232 program download test via CIF01 cable + verify PID run)
  • Technical support for:
    • Suffix confirmation (T=NPN transistor vs R=Relay; D=24V DC in vs A=100–240V AC in; H=high-function vs base)
    • CPM2A vs CPM2AH choice (need expansion? → CPM2AH; simple standalone 30pt? → CPM2A-30CDT-D fine)
    • CX-Programmer connection (CPM1-CIF01 RS-232 or USB-CIF02 → PC → CX-P → Online → Transfer)
    • RS-485 Port 2 usage (Modbus RTU slave config — ladder TXD/RXD instructions — connect to inverter/weigh scale)
    • NT HMI linking (Port 1 RS-232 → NT11/NT20/NT31 via NT Link protocol — cable CPM1-CIF01 to NT’s RS-232)
    • Migration advice (CPM2A → CP1L / CP1E — wiring NOT compatible, program ~70% auto-converts, rest manual; if keeping spare for existing machine → stay CPM2A)
    • Battery / super-cap backup (CPM1-BAT01 — if long power-off expected, add battery)
  • Optional: CPM1-CIF01 (RS-232 cable), USB-CIF02 (USB cable), CPM1-BAT01 (backup battery), CPM1A expansion I/O (CPM1A-20EDR / CPM1A-8ER — for CPM2AH only), NT-series HMI (NT11, NT20)

Delivery Time

  • Standard delivery: 3-5 working days (NOS stock — CPM2A legacy)
  • Express shipping available upon request

Why Choose Our Store

  • Genuine Omron CPM2A / CPM2AH — NOS from verified channels (super-cap / battery shelf-life checked)
  • Global supply network with competitive pricing on legacy Omron micro PLCs
  • Expertise in CPM2A system (suffix decode, CX-P download via CIF01, RS-485 Port 2 Modbus, NT HMI link, CPM2A→CP1L migration)
  • Comprehensive technical documentation (CPM2A terminal layout, RS-232/485 pinout, CX-P connect screenshot, migration comparison table)
  • Responsive customer service and support

Applications

  • Legacy Machine Spares / Repair: Exact CPM2A-30CDT-D / 40CDR-D / CPM2AH-20CDR-A — drop-in for existing production machines (packaging, labeling, small CNC, textile).
  • Small Standalone Machine (OEM): 30pt CPM2A-30CDT-D — transistor out drives SSR/solenoids; RS-485 Port 2 talks to PowerFlex / inverter via Modbus RTU; PID built-in for temp/pressure loop.
  • Retrofit from C200H / C20 / C28: CPM2A was the migration path FROM C20/C28/C200Hα smaller racks — if maintaining old line, CPM2A is the spare.
  • HMI + Small Logic: Port 1 RS-232 → NT11/NT20 HMI (Omron NT Link) — small operator panel + CPM2A logic = classic Omron stack (pre-CP1H/NA HMI era).
  • Keep-Production-Running Strategy: Many plants still run CPM2A 20+ years — stock NOS as cold spare; plan migration to CP1L/CP1E during next major downtime (wiring change required).