Allen-Bradley PanelView Standard 2711-K10C8 — 10″ Keypad HMI, DH+ / RS-232, 2711-T6C8L1 / 2711-K10C1 etc.

Allen-Bradley PanelView Standard 2711-K10C8 — 10″ Keypad HMI, DH+ / RS-232, 2711-T6C8L1 / 2711-K10C1 etc. | Shop On eBay

Factory New Parts : Warranty 12 Months​
Refurbished Units : Warranty 3-6 Months​
Tested & Certified | Ships Worldwide​
Technical / Configuration Support Available​
Warranty Extension and Urgent Delivery supported. Get your quote or lead time now !

Description

The listed 2711-K10C8, 2711-T6C8L1, 2711-T6C9L1, 2711-K10C1, 2711-K10C10, 2711-K10C​ are Allen-Bradley PanelView Standard (legacy) Operator Interface Terminals​ — the classic line of industrial HMIs for Rockwell Automation / Allen-Bradley SLC 500, PLC-5, and MicroLogix systems (some also support ControlLogix via MSG or older DF1/DH+).
  • 2711-K10C8​ → PanelView Standard 1000 (10″ display), Keypad (Function keys only — no touch), DH+ (Allen-Bradley Data Highway Plus — 57.6 / 115.2 / 230.4 kbps typical) AND RS-232 Printer/Download port, 256 Kbytes application memory, 10″ STN color or monochrome? Actually -K10C8 = Color Active Matrix TFT (10″ 640×480 VGA)​ — “C” = Color TFT; “G” = Monochrome. “8” in suffix often = DH+ & RS-232 (C8 = DH+ + RS-232; C9 = EtherNet/IP + RS-232; C1 = DH-485 for MicroLogix; C10L1 = DH+ & RS-232 with long-label support / Series B firmwareetc.).
    The 2711-K10C8​ is a 10-inch Keypad-only Color TFT PanelView Standard, communicating natively with PLC-5 / SLC 5/04 over DH+, or can be configured for SLC 5/03 (DH-485) with different cable if using DH-485 models — but -K10C8 is DH+ primary.
  • 2711-T6C8L1​ → PanelView Standard 600 (6″) Touch Screen only (no keys), Color TFT, DH+ & RS-232, Series B/L1 (long-label firmware) — “L1” denotes Series B hardware with long tag name support (for RSLogix 5000 v16+ alias tags or long SLC tag names in PVPlus migrated apps — on Standard it’s limited but L1 = longer descriptor support).
  • 2711-T6C9L1​ → Same 6″ Touch Color but EtherNet/IP (10/100) + RS-232​ — for connection to ControlLogix/CompactLogix or SLC 5/05 via Ethernet.
  • 2711-K10C1​ → 10″ Keypad Color — DH-485 (MicroLogix 1000/1100/1200 / SLC 5/03)​ + RS-232 — NOT DH+! Use with MicroLogix.
  • 2711-K10C10 / 2711-K10C (no suffix or partial)​ → Often shorthand for -K10C8 / -K10C9 / -K10C1 — verify full 20-char code: e.g., 2711-K10C10 = 10″ Keypad Color, EtherNet/IP + RS-232​ (C10 = ENET + RS-232 on PanelView Standard 1000).
All PanelView Standard terminals are configured with PanelBuilder 32 software (legacy — runs on Windows XP / Win7 32-bit recommended)​ — NOT with FactoryTalk View Studio (that’s for PanelView Plus / 5000 series). .PBA files are the project format.
⚠️ PanelView Standard ≠ PanelView Plus!​ These are discontinued legacy units​ — replaced by PanelView Plus 6 / 7 (2711P-T10C…). If you are designing new, consider PanelView Plus 6 10″ (2711P-T10C22D8S / 2711P-K10C22D8S) which supports newer protocols (EtherNet/IP native to Logix) and FactoryTalk View ME. But if you need exact replacement for an existing 2711-K10C8 — this is the correct part.

Key Features (2711-K10C8 / 2711-T6C8L1 family)

  • Display: 10″ (K10) = 640×480 VGA (TFT Color or Mono — C=TFT Color); 6″ (T6) = 320×240 QVGA (C=TFT Color)
  • Input: K = Keypad only (F-keys + nav — 20+ programmable function keys); T = Touch only; TK combo available on some Plus but Standard = K or T only
  • Communications: DH+ (C8), EtherNet/IP (C9/C10), DH-485 (C1), RS-232 (Printer/Download — present on most)
  • Configuration SW: PanelBuilder 32 (Allen-Bradley / Rockwell Software — legacy)
  • Memory: 256 KB (typical for Standard series — enough for moderate screens, alarms, macros)
  • Country of Origin: USA (Rockwell Automation / Allen-Bradley)

Model & Capability Table (Listed PanelView Standard Items — Indicative)

Model
Size / Input
Display
Comm. Ports
Typical Use
2711-K10C8​ (main)
10″ / Keypad only
Color TFT (640×480)
DH+ (Data Highway Plus) + RS-232 (print/download)
PLC-5 / SLC 5/04 over DH+ — classic plant floor HMI
2711-T6C8L1
6″ / Touch only
Color TFT (320×240)
DH+ + RS-232 — L1=Series B (extended desc.)
Smaller DH+ HMI — e.g., local station on DH+ network
2711-T6C9L1
6″ / Touch only
Color TFT
EtherNet/IP + RS-232​ — L1 Series B
Connect to ControlLogix/CompactLogix or SLC 5/05 via ENET
2711-K10C1
10″ / Keypad
Color TFT
DH-485 + RS-232
MicroLogix 1000/1100/1200 or SLC 5/03 (DH-485)
2711-K10C10 (full 2711-K10C10=2711-K10C10…)
10″ / Keypad
Color TFT
EtherNet/IP + RS-232
Logix family via ENET (legacy Standard — for new design use PV Plus 6)
2711P-T10C22D8S
10″ / Touch (PV Plus 6)
Color TFT
EtherNet/IP + RS-232/485
Modern replacement — FactoryTalk View ME
⚠️ Critical Selection & Install Notes:
  1. Know Your PLC Network:
    • PLC-5 / SLC 5/04 with DH+ → use C8 (DH+)​ models (2711-K10C8, 2711-T6C8L1).
    • SLC 5/03 or MicroLogix 1000/1100/1200 (DH-485) → use C1 (DH-485)​ models (2711-K10C1).
    • SLC 5/05 or ControlLogix/CompactLogix with Ethernet → use C9/C10 (EtherNet/IP)​ models (2711-T6C9L1, 2711-K10C10).
      Using wrong comms suffix = cannot talk to PLC!
  2. PanelBuilder 32 Required: Projects are created/configured in PanelBuilder 32​ (Rockwell legacy SW — not Free; often on old install CDs or downloadable with valid TechConnect). File extension .PBA. Cannot open/edit in FactoryTalk View Studio (that’s for PanelView Plus). If you have old .PBAfile — download to 2711-K10C8 via serial (RS-232) or DH+ (if DH+ model).
  3. DH+ Wiring: DH+ uses Shielded Twisted Pair (STP) — Belden 9463 or equivalent — Red/Black (+/- polarity matters on some nodes but DH+ is polarity insensitive typically — terminate both ends with 150Ω resistor in blue tap connector 1785-BCM/1786-CP). PanelView DH+ port is a 3-pin terminal (Signal A, Signal B, Shield — shield to earth ground at one point).
  4. Replacement Consideration: If you’re NOT replacing an existing 2711-… but building new, strongly consider PanelView Plus 6 (2711P-T10C22D8S — Touch; 2711P-K10C22D8S — Keypad/Touch combo on Plus 6 10″ — note Plus series K=keypad+touch combo or T=touch only)​ programmed with FactoryTalk View ME (V6–V12+)​ — far more capable, still supports DH+ via comm card or via passthrough from Logix ENET bridge. But 2711-K10C8 is the correct legacy spare.
  5. Power / Cutout: 2711-K10C8 requires 120/240 V AC or 24 V DC (check suffix last digits: -L1 usually = 120V AC; -L2 = 240V AC; -L3 = 24V DC — confirm by full 20-char: e.g., 2711-K10C8L1 = 120V AC input, Series B/L1 firmware). Cutout ~ 243 mm × 188 mm (check A-B drawing 2711-UM…). Weight ~ 3.2 kg.

Technical Specifications (Representative — 2711-K10C8, 10″ Keypad Color TFT, DH+ & RS-232, 120V AC)

Parameter
Specification
Model / Order Code
2711-K10C8 (Allen-Bradley PanelView Standard 1000 — Keypad, Color TFT, DH+ & RS-232)
Series
PanelView Standard (legacy — discontinued — replaced by PanelView Plus 6/7)
Display Size / Type
10.4″ TFT Color Active Matrix — 640 × 480 pixels (VGA) — 16 or 256K colors depending on firmware (Std typically 16/256 pseudo-color)
Input Method
Keypad only​ — 20+ programmable function keys (F1–F20/F22), navigation keys (↑↓←→, Enter, Clear, numeric entry via overlay) — no touchscreen
Communication Ports
1 × DH+ (Data Highway Plus — 57.6k–230.4k bps — 3-pin terminal block A/B/Shield); 1 × RS-232 (DB9 female — for printer or program download via 1761-CBL-PM02 cable)
Application Memory
256 KB (typical — holds screens, alarms, macros, tags — enough for moderate complexity)
Power Input
85–264 V AC (47–63 Hz) typical for -L1 suffix; 24 V DC option on -L3 — verify by full 20-char code
Backlight Life
~ 50,000 hrs (typical — user-replaceable on some; sealed unit on others — check service kit)
NEMA / IP Rating
NEMA 12 / 13 / 4X (indoor — with gasket), IP65 (front) — UL / cUL / CE
Config Software
PanelBuilder 32​ (Rockwell Software — legacy — runs on Windows XP / Win7 32-bit recommended) — project file .PBA
Operating Temp.
0 … +55 °C (some sources say 0…+50°C — check A-B manual 2711-UM014)
Dimensions (W×H×D)
~ 295 mm × 235 mm × 95 mm (bezel); Cutout: ~ 243 mm × 188 mm (refer to A-B dwg)
Weight
~ 3.0 – 3.5 kg
Country of Origin
USA (Rockwell Automation)

Warranty & After-Sales

  • Factory new units: 12 months warranty (NOS / new old stock — tested prior ship)
  • Refurbished units: 3-6 months warranty (power-on + download sample .PBA via RS-232 → verify screen render + DH+ node comms to test PLC if avail)
  • Technical support for:
    • Model cross-check (confirm DH+ vs ENET vs DH-485 suffix matches your PLC network — C8=DH+, C1=DH-485, C9/C10=ENET)
    • PanelBuilder 32 upload/download procedure (RS-232 cable 1761-CBL-PM02 — AB standard; DH+ download via RSLinx + PB32)
    • DH+ network wiring & termination (Belden 9463 STP, 150Ω terminator at both ends — red/black polarity, shield grounded at one point)
    • Power / cutout dimension verification (120V AC vs 24V DC — check -L1/-L2/-L3 suffix)
    • Upgrade path advice (PanelView Standard → PanelView Plus 6 — 2711P-T10C22D8S (touch) or 2711P-K10C22D8S (keypad+limited touch on Plus — actual K10C22 has keys+some touch areas) — note: application must be re-developed in FT View ME (.MER) — no direct import from PanelBuilder 32 .PBA though Rockwell has a migration guide/tool)
    • Cross-ref to obsolete DH-485 (C1) or ENET (C9/C10) versions if you listed those
  • Optional: 1761-CBL-PM02 (RS-232 programming cable), DH+ drop cable (1786-CP / 1786-BJC), 150Ω DH+ terminator (1786-TPR), DH+ tap (1785-BCM / 1786-TPS), PanelBuilder 32 software (if available)

Delivery Time

  • Standard delivery: 3-5 working days (NOS stock — PanelView Standard legacy often NOS)
  • Express shipping available upon request

Why Choose Our Store

  • Genuine Allen-Bradley PanelView Standard terminals — not reflashed/aftermarket LCD (backlight evenness & DH+ PHY critical)
  • Global supply network with competitive pricing on legacy A-B spares
  • Expertise in A-B PanelView Standard legacy (DH+ wiring, PB32 download, C8/C1/C9 suffix differentiation, migration to PV Plus)
  • Comprehensive technical documentation (cutout dwg, DH+ daisy-chain diagram, PB32 download steps screenshot, RS-232 cable p/n)
  • Responsive customer service and support

Applications

  • Plant Floor HMI on DH+: PLC-5 / SLC 5/04 networks — machine status, setpoint entry via F-keys, alarm ack (2711-K10C8).
  • Local Operator Station (6″ DH+ or ENET): Smaller footprint — 2711-T6C8L1 (DH+) or 2711-T6C9L1 (ENET).
  • MicroLogix / SLC 5/03 DH-485 Link: 2711-K10C1 (C1 suffix) — small machine with MicroLogix.
  • Retrofit / Exact Spare: Drop-in for existing 2711-K10C8 — download original .PBA via PanelBuilder 32 → run.
  • Obsolescence Bridge: Keep as spare while planning migration to PanelView Plus 6/7 + FactoryTalk View ME.

Reviews

There are no reviews yet.

Be the first to review “Allen-Bradley PanelView Standard 2711-K10C8 — 10″ Keypad HMI, DH+ / RS-232, 2711-T6C8L1 / 2711-K10C1 etc.”